Industrial safety

Gas, heat and people in hazardous areas, with the site's protocol.

What it solves

The emergency protocol usually lives in a folder. When the alarm sounds, whoever is on shift does what they remember, and what they remember depends on how long they have held the post.

What gets measured here

Every signal, with the standard behind it

  • 10 % LEL

    First warning · 20 % evacuate · the threshold is the compound's, not a generic one

    Concentración de gas

    Detector reading in ppm or as a percentage of the lower flammable limit, with the compound's own threshold rather than a generic one.

    LEL · OSHA PEL · NIOSH IDLH
  • 1 ppm

    H₂S · CO 25 · NH₃ 25 · Cl₂ 0.5 — the Mexican standard's own

    Exposición ocupacional

    The exposure limit that applies in Mexico for each substance, not one copied from another country.

    NOM-010-STPS-2014
  • > 15 K

    Over the twin component · 4–15 scheduled · 1–3 investigate

    Punto caliente eléctrico

    ΔT over the reference decides the action class. An absolute degree says nothing without its comparison.

    NETA MTS · NFPA 70B

The full catalogue is 311 standards across fourteen domains, and it lives inside the platform — next to the field where the number goes — not in an appendix to the manual.

A concrete case

A fixed thermal camera on a post inside a fuel pump room, with fire-risk signage, and the thermal view marking a motor at 92.4 °C.
Fuel pump room · the fixed camera measures without anyone entering the classified zone.

The classified zone is watched without entering it

The value of a fixed camera in a pump room is not that it records: it is that it measures without anyone having to walk into a hazardous atmosphere to take a reading. The motor crossed its seventy-degree limit at three in the morning and the alert went out by itself. At that hour there is no round.

  • Temperature in a classified zone

    IEC 60079 · NFPA 70B

    Measuring without entering. The watching equipment stays outside the zone and whoever works inside takes no readings by hand.

  • Hot spot against its limit

    NETA MTS 100.18

    The motor at 92.4 °C against a 70 °C limit. The alarm is not triggered by a colour: it is triggered by a degree against a threshold with a standard.

  • Gas leak detection

    EPA Method 21

    The plume is seen before it reaches the point detector, and the record says where it was and at what time.

The protocol arrives with the alarm

The steps that appear are the ones for that site, that role and that hazard level, with the standard behind them and the clock running. Not a generic checklist.