The building, the services and the hotel's security, in one view.

Video, people counting, visitors and parcels, plant-room thermography, sensors and work orders in the same console. Nothing inside guest rooms: the platform watches common areas, service entrances and equipment, and the video stays on the hotel's local server.

SecurityThermographyAccess Control
Hotels and hospitality

Plant room · in action

The hotel's chiller, measured by the thermal camera.

Each chiller point is measured against its template thresholds —compressor, condenser, motor and panel, each with its standard— and if the trend continues, the warning arrives hours before the rooms stop cooling.

The hotel's chiller, measured by the thermal camera.
Chiller 1 · Plant room
  1. 1 · Compressor84.6 °CWarningWarning 80 · Critical 100
  2. 2 · Condenser48.3 °CNormalWarning 55 · Critical 70
  3. 4 · Compressor motor68.2 °CNormalWarning 75 · Critical 90
  4. 8 · Electrical panel41.0 °CNormalWarning 55 · Critical 70

Septem PredictIA · 1 · Compressor · projection to critical — If the trend holds, it would reach the critical threshold (100.0°C) in ~6.0 h.

Pool · in action

How many guests are at the pool, counted by the camera.

The access camera counts each person going in and out, and occupancy is compared with the space's capacity. After hours, the same zone arms itself and alarms if someone enters.

How many guests are at the pool, counted by the camera.Person
PoolPool · Downtown HotelOccupancy now · Normal1845 % of 40 people
Entries since 09:00
142
Exits
124
Exits per hour
15
Last count a moment ago · 1 entrance

Ready today

Works today in real installations.

  • Video and Asset ViewLobby, corridors, parking, pool and perimeter, live and recorded, on one screen.
  • Occupancy per spaceLobby, restaurant, pool and event rooms, with an «Almost full» warning.
  • Visitors, reception and parcelsSuppliers and visitors with a temporary QR, reception kiosk and parcels with a notice to the recipient.
  • Service entrancesDoors, readers and intercom for service and restricted areas.
  • Plant-room thermographyChiller, boiler, switchboards, pool and cistern pumps, and emergency generator, each with its template.
  • Work ordersPreventive and corrective maintenance with SLA, with a hotel failure catalog: hot water, air, pumps, emergency generator.
  • LoRaWAN sensorsWater leaks, door contacts, cold-room temperature and panic buttons for staff.
  • Zones armed by schedulePool, gym or rooftop closed: if someone enters after hours, it alarms.

Validated at your site

The code exists; we test it with your equipment before committing to it.

  • Natural Search and attribute searchFind in recordings by description, color or vehicle type.
  • Plates at the parking lotPlate reading at the entrance, with the hotel's plate camera.
  • Energy per areaEnergy submetering per building or area, depending on the installed meters.
  • Building HVACReading air handlers and equipment over BACnet, read-only.
  • Person downIn common areas and parking, with the hotel's cameras.
  • Paging and welcome screensLoudspeaker messages and screens in the lobby and event rooms.

Recommended hardware

What is enough, measured. What we have not measured, we say so.

Analytics run on the on-site server, at the plant. This table comes from dated measurements and the installer's rules; above what was measured, the equipment is sized by measuring at your site before committing to a number.

On-site server by camera count

CamerasRecording and live videoAnalyticsServerStatus
1 to 5The resolution and frame rate you set on the camera, up to 4K, without re-encodingAI analyses the substream at 3 frames/s, only when there is motion4 cores · 16 GB RAM · 100 GB for the system + the video diskMeasured: 2 cores were the limit for 5 cameras with AI
Any4K camera without substreamAI would have to read the full 4K streamEnable the camera substream: it records in 4K and AI reads the substreamMeasured: with the 4K stream alone, 2 cores were not enough
6 or moreThe same: growing never lowers resolution or frame rateThe same, on every cameraA server with more cores, or several Archivers (Multi-Archiver) sharing the camerasSized with the test kit at your site

Recording copies the camera stream as it arrives, without re-encoding: what grows with the cameras is disk, network and cores for analytics, not quality. Installer minimum: 8 GB RAM (it will not install with less) and 30 GB free; recommended: 4 cores, 16 GB and 100 GB.

A hotel usually has cameras spread across many areas: size by how many the AI analyses at once. Parking plate cameras run at 6 frames/s and are counted separately.

What each analytic costs

AnalyticModel and inputMeasured time per frame (CPU, no GPU)Default rate
People and vehiclesOwn detector · 640 × 640385 to 465 ms, depending on hardware3 frames/s per camera, only when there is motion
Plate readingFull frame 2560 × 1440349 ms on 2 cores · 95.9 % exact plates over 121 frames6 frames/s on the plate camera
Attribute and text searchVisual fingerprint · 224 × 224 per crop≈ 490 ms per cropOnce per detected person or vehicle
PPE (hard hat and vest)PPE detector · 640 × 640No published per-camera measurementEvery 8 s, up to 2 people per pass

Disk per camera per day

Resolution (H.265, 15 frames/s)Continuous recordingMotion only
1080p≈ 25 GB≈ 7 GB
4 MP≈ 44 GB≈ 13 GB
4K≈ 99 GB≈ 30 GB

Estimate from the platform's storage planner (1100 kbps per megapixel in H.265). Measured in the lab: 14 cameras at 1080p H.264, 15 frames/s recorded 518 GB per day.

On-Premises and Hybrid Cloud

In both modes video, photos of people and analytics stay on the on-site server; the cloud computes nothing that depends on the number of cameras. In Hybrid Cloud the substream is uploaded only while someone is watching (0.5 to 2 Mbps per camera, a design value, not measured).

When the hardware is not enough

Recording and live video are never touched. With the CPU saturated, analytics drop to half the frames; if it continues, they pause; and after 5 minutes the console shows «insufficient hardware». Today on-site analytics run on CPU: there is no GPU acceleration.

Illustrative footage generated for this page. The readings, thresholds, steps and status of each function are the ones the platform shows.

SEE. UNDERSTAND. ACT.

A demo with your cameras and your equipment, in your language. If we don't do something yet, we will tell you.